id: | leodagan | ||||||||||||
description: | System | ||||||||||||
product: | PowerEdge 2500 | ||||||||||||
vendor: | Dell Computer Corporation | ||||||||||||
serial: | 5WML90J | ||||||||||||
width: | 32 bits | ||||||||||||
capabilities: | smp-1.4 smp | ||||||||||||
configuration: |
|
id: | core |
description: | Motherboard |
physical id: | 0 |
id: | firmware |
description: | BIOS |
vendor: | Dell Computer Corporation |
physical id: | 0 |
version: | A07 (08/15/2003) |
size: | 64KiB |
capacity: | 448KiB |
capabilities: | isa pci pnp upgrade shadowing escd cdboot bootselect edd int13floppytoshiba int13floppy360 int13floppy1200 int13floppy720 int5printscreen int9keyboard int14serial int17printer int10video acpi biosbootspecification netboot |
id: | cpu:0 |
description: | CPU |
product: | Pentium III (Coppermine) |
vendor: | Intel Corp. |
physical id: | 400 |
bus info: | cpu@0 |
version: | 6.8.10 |
slot: | Proc_1 |
size: | 1GHz |
capacity: | 1533MHz |
width: | 32 bits |
clock: | 133MHz |
capabilities: | boot fpu fpu_exception wp de tsc msr pae cx8 apic mtrr cmov pat mmx fxsr sse |
id: | cache:0 |
description: | L1 cache |
physical id: | 700 |
size: | 32KiB |
capacity: | 32KiB |
capabilities: | internal write-back |
id: | cache:1 |
description: | L2 cache |
physical id: | 701 |
size: | 256KiB |
capacity: | 2MiB |
capabilities: | pipeline-burst internal write-back unified |
id: | cpu:1 |
description: | CPU |
product: | Pentium III (Coppermine) |
vendor: | Intel Corp. |
physical id: | 401 |
bus info: | cpu@1 |
version: | 6.8.10 |
slot: | Proc_2 |
size: | 1GHz |
capacity: | 1533MHz |
width: | 32 bits |
clock: | 133MHz |
capabilities: | fpu fpu_exception wp de tsc msr pae cx8 apic mtrr cmov pat mmx fxsr sse |
id: | cache:0 |
description: | L1 cache |
physical id: | 702 |
size: | 32KiB |
capacity: | 32KiB |
capabilities: | internal write-back |
id: | cache:1 |
description: | L2 cache |
physical id: | 703 |
size: | 256KiB |
capacity: | 2MiB |
capabilities: | pipeline-burst internal write-back unified |
id: | memory |
description: | System Memory |
physical id: | 1000 |
slot: | System board or motherboard |
size: | 1152MiB |
capacity: | 2GiB |
id: | bank:0 |
description: | DIMM SDRAM Synchronous 133 MHz (7.5 ns) |
physical id: | 0 |
slot: | DIMM_A |
size: | 64MiB |
width: | 64 bits |
clock: | 133MHz (7.5ns) |
id: | bank:1 |
description: | DIMM SDRAM Synchronous 133 MHz (7.5 ns) |
physical id: | 1 |
slot: | DIMM_B |
size: | 64MiB |
width: | 64 bits |
clock: | 133MHz (7.5ns) |
id: | bank:2 |
description: | DIMM SDRAM Synchronous 133 MHz (7.5 ns) |
physical id: | 2 |
slot: | DIMM_C |
size: | 512MiB |
width: | 64 bits |
clock: | 133MHz (7.5ns) |
id: | bank:3 |
description: | DIMM SDRAM Synchronous 133 MHz (7.5 ns) |
physical id: | 3 |
slot: | DIMM_D |
size: | 512MiB |
width: | 64 bits |
clock: | 133MHz (7.5ns) |
id: | bank:4 |
description: | DIMM SDRAM Synchronous 133 MHz (7.5 ns) [empty] |
physical id: | 4 |
slot: | DIMM_E |
width: | 64 bits |
clock: | 133MHz (7.5ns) |
id: | bank:5 |
description: | DIMM SDRAM Synchronous 133 MHz (7.5 ns) [empty] |
physical id: | 5 |
slot: | DIMM_F |
width: | 64 bits |
clock: | 133MHz (7.5ns) |
id: | pci:0 | |||
description: | Host bridge | |||
product: | CNB20HE Host Bridge | |||
vendor: | Broadcom | |||
physical id: | 100 | |||
bus info: | pci@0000:00:00.0 | |||
version: | 23 | |||
width: | 32 bits | |||
clock: | 33MHz | |||
configuration: |
|
id: | network:0 | |||||||||||||||||||||||||||||||||||||||||||||
description: | Ethernet interface | |||||||||||||||||||||||||||||||||||||||||||||
product: | 82557/8/9/0/1 Ethernet Pro 100 | |||||||||||||||||||||||||||||||||||||||||||||
vendor: | Intel Corporation | |||||||||||||||||||||||||||||||||||||||||||||
physical id: | 4 | |||||||||||||||||||||||||||||||||||||||||||||
bus info: | pci@0000:00:04.0 | |||||||||||||||||||||||||||||||||||||||||||||
logical name: | eth1 | |||||||||||||||||||||||||||||||||||||||||||||
version: | 08 | |||||||||||||||||||||||||||||||||||||||||||||
serial: | 00:06:5b:3a:3b:1e | |||||||||||||||||||||||||||||||||||||||||||||
size: | 100MB/s | |||||||||||||||||||||||||||||||||||||||||||||
capacity: | 100MB/s | |||||||||||||||||||||||||||||||||||||||||||||
width: | 32 bits | |||||||||||||||||||||||||||||||||||||||||||||
clock: | 33MHz | |||||||||||||||||||||||||||||||||||||||||||||
capabilities: | pm bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd autonegotiation | |||||||||||||||||||||||||||||||||||||||||||||
configuration: |
|
id: | network:1 | ||||||||||||||||||||||||||||||||||||||||||
description: | Ethernet interface | ||||||||||||||||||||||||||||||||||||||||||
product: | DGE-528T Gigabit Ethernet Adapter | ||||||||||||||||||||||||||||||||||||||||||
vendor: | D-Link System Inc | ||||||||||||||||||||||||||||||||||||||||||
physical id: | 8 | ||||||||||||||||||||||||||||||||||||||||||
bus info: | pci@0000:00:08.0 | ||||||||||||||||||||||||||||||||||||||||||
logical name: | eth0 | ||||||||||||||||||||||||||||||||||||||||||
version: | 10 | ||||||||||||||||||||||||||||||||||||||||||
serial: | 00:17:9a:3a:77:93 | ||||||||||||||||||||||||||||||||||||||||||
size: | 1GB/s | ||||||||||||||||||||||||||||||||||||||||||
capacity: | 1GB/s | ||||||||||||||||||||||||||||||||||||||||||
width: | 32 bits | ||||||||||||||||||||||||||||||||||||||||||
clock: | 66MHz | ||||||||||||||||||||||||||||||||||||||||||
capabilities: | pm bus_master cap_list ethernet physical tp 10bt 10bt-fd 100bt 100bt-fd 1000bt-fd autonegotiation | ||||||||||||||||||||||||||||||||||||||||||
configuration: |
|
id: | display | ||||||
description: | VGA compatible controller | ||||||
product: | Rage XL | ||||||
vendor: | ATI Technologies Inc | ||||||
physical id: | e | ||||||
bus info: | pci@0000:00:0e.0 | ||||||
version: | 27 | ||||||
width: | 32 bits | ||||||
clock: | 33MHz | ||||||
capabilities: | pm vga_controller bus_master cap_list | ||||||
configuration: |
|
id: | isa | |||||||||
description: | ISA bridge | |||||||||
product: | OSB4 South Bridge | |||||||||
vendor: | Broadcom | |||||||||
physical id: | f | |||||||||
bus info: | pci@0000:00:0f.0 | |||||||||
version: | 50 | |||||||||
width: | 32 bits | |||||||||
clock: | 33MHz | |||||||||
capabilities: | isa bus_master | |||||||||
configuration: |
|
id: | ide | |||||||||
description: | IDE interface | |||||||||
product: | OSB4 IDE Controller | |||||||||
vendor: | Broadcom | |||||||||
physical id: | f.1 | |||||||||
bus info: | pci@0000:00:0f.1 | |||||||||
version: | 00 | |||||||||
width: | 32 bits | |||||||||
clock: | 33MHz | |||||||||
capabilities: | ide bus_master | |||||||||
configuration: |
|
id: | ide:0 |
description: | IDE Channel 0 |
physical id: | 0 |
bus info: | ide@0 |
logical name: | ide0 |
clock: | 33MHz |
id: | cdrom | ||||||
description: | IDE CD-ROM | ||||||
product: | TEAC CD-ROM CD-224E | ||||||
physical id: | 0 | ||||||
bus info: | ide@0.0 | ||||||
logical name: | /dev/hda | ||||||
version: | 3.7D | ||||||
capabilities: | packet atapi cdrom removable nonmagnetic dma lba iordy audio | ||||||
configuration: |
|
id: | ide:1 |
description: | IDE Channel 1 |
physical id: | 1 |
bus info: | ide@1 |
logical name: | ide1 |
clock: | 33MHz |
id: | usb | ||||||||||||
description: | USB Controller | ||||||||||||
product: | OSB4/CSB5 OHCI USB Controller | ||||||||||||
vendor: | Broadcom | ||||||||||||
physical id: | f.2 | ||||||||||||
bus info: | pci@0000:00:0f.2 | ||||||||||||
version: | 04 | ||||||||||||
width: | 32 bits | ||||||||||||
clock: | 33MHz | ||||||||||||
capabilities: | ohci bus_master | ||||||||||||
configuration: |
|
id: | usbhost | |||||||||
product: | OHCI Host Controller | |||||||||
vendor: | Linux 2.6.26-2-xen-686 ohci_hcd | |||||||||
physical id: | 1 | |||||||||
bus info: | usb@1 | |||||||||
logical name: | usb1 | |||||||||
version: | 2.06 | |||||||||
capabilities: | usb-1.10 | |||||||||
configuration: |
|
id: | pci:1 | |||
description: | Host bridge | |||
product: | CNB20HE Host Bridge | |||
vendor: | Broadcom | |||
physical id: | 101 | |||
bus info: | pci@0000:00:00.1 | |||
version: | 01 | |||
width: | 32 bits | |||
clock: | 33MHz | |||
configuration: |
|
id: | pci:2 | |||
description: | Host bridge | |||
product: | CNB20HE Host Bridge | |||
vendor: | Broadcom | |||
physical id: | 102 | |||
bus info: | pci@0000:00:00.2 | |||
version: | 01 | |||
width: | 32 bits | |||
clock: | 33MHz | |||
configuration: |
|
id: | pci:3 | |||
description: | Host bridge | |||
product: | CNB20HE Host Bridge | |||
vendor: | Broadcom | |||
physical id: | 103 | |||
bus info: | pci@0000:00:00.3 | |||
version: | 01 | |||
width: | 32 bits | |||
clock: | 33MHz | |||
configuration: |
|
id: | pci:4 |
description: | PCI bridge |
product: | 80960RM (i960RM) Bridge |
vendor: | Intel Corporation |
physical id: | 2 |
bus info: | pci@0000:01:02.0 |
version: | 01 |
width: | 32 bits |
clock: | 33MHz |
capabilities: | pci pm normal_decode bus_master |
id: | scsi:0 | |||||||||
description: | SCSI storage controller | |||||||||
product: | RAID subsystem HBA | |||||||||
vendor: | Adaptec | |||||||||
physical id: | 4 | |||||||||
bus info: | pci@0000:02:04.0 | |||||||||
version: | 01 | |||||||||
width: | 64 bits | |||||||||
clock: | 66MHz | |||||||||
capabilities: | scsi pm bus_master cap_list | |||||||||
configuration: |
|
id: | scsi:1 | |||||||||||||||
description: | SCSI storage controller | |||||||||||||||
product: | AIC-7899P U160/m | |||||||||||||||
vendor: | Adaptec | |||||||||||||||
physical id: | 4.1 | |||||||||||||||
bus info: | pci@0000:02:04.1 | |||||||||||||||
logical name: | scsi1 | |||||||||||||||
version: | 01 | |||||||||||||||
width: | 64 bits | |||||||||||||||
clock: | 66MHz | |||||||||||||||
capabilities: | scsi pm bus_master cap_list scsi-host | |||||||||||||||
configuration: |
|
id: | storage | |||||||||
description: | RAID bus controller | |||||||||
product: | PowerEdge Expandable RAID Controller 3/Di | |||||||||
vendor: | Dell | |||||||||
physical id: | 2.1 | |||||||||
bus info: | pci@0000:01:02.1 | |||||||||
logical name: | scsi0 | |||||||||
version: | 01 | |||||||||
width: | 32 bits | |||||||||
clock: | 33MHz | |||||||||
capabilities: | storage pm bus_master emulated | |||||||||
configuration: |
|
id: | disk:0 | |||
description: | SCSI Disk | |||
physical id: | 0.0.0 | |||
bus info: | scsi@0:0.0.0 | |||
logical name: | /dev/sda | |||
size: | 67GiB (72GB) | |||
capabilities: | partitioned partitioned:dos | |||
configuration: |
|
id: | volume:0 | |||||||||||||||||||||
description: | Linux filesystem partition | |||||||||||||||||||||
vendor: | Linux | |||||||||||||||||||||
physical id: | 1 | |||||||||||||||||||||
bus info: | scsi@0:0.0.0,1 | |||||||||||||||||||||
logical name: | /dev/sda1 | |||||||||||||||||||||
logical name: | /boot | |||||||||||||||||||||
version: | 1.0 | |||||||||||||||||||||
serial: | fe9a7e39-ec83-453d-89fd-22bf4d1e21c4 | |||||||||||||||||||||
size: | 94MiB | |||||||||||||||||||||
capacity: | 94MiB | |||||||||||||||||||||
capabilities: | primary bootable large_files huge_files recover ext2 initialized | |||||||||||||||||||||
configuration: |
|
id: | volume:1 |
description: | Linux LVM Physical Volume partition |
physical id: | 2 |
bus info: | scsi@0:0.0.0,2 |
logical name: | /dev/sda2 |
serial: | t6JA16-Aw11-NZeb-wulK-187U-Fk38-9gsLs6 |
size: | 67GiB |
capacity: | 67GiB |
capabilities: | primary multi lvm2 |
id: | disk:1 |
description: | SCSI Disk |
physical id: | 1.0.0 |
bus info: | scsi@0:1.0.0 |
id: | disk:2 |
description: | SCSI Disk |
physical id: | 1.1.0 |
bus info: | scsi@0:1.1.0 |
id: | disk:3 |
description: | SCSI Disk |
physical id: | 1.2.0 |
bus info: | scsi@0:1.2.0 |
id: | processor | |||
description: | SCSI Processor | |||
product: | 1x6 U2W SCSI BP | |||
vendor: | DELL | |||
physical id: | 1.6.0 | |||
bus info: | scsi@0:1.6.0 | |||
version: | 1.29 | |||
serial: | 1 | |||
configuration: |
|
id: | network:0 | |||||||||||||||||||||
description: | Ethernet interface | |||||||||||||||||||||
physical id: | 1 | |||||||||||||||||||||
logical name: | xenbr997 | |||||||||||||||||||||
serial: | 00:17:9a:3a:77:93 | |||||||||||||||||||||
capabilities: | ethernet physical | |||||||||||||||||||||
configuration: |
|
id: | network:1 | ||||||
description: | Ethernet interface | ||||||
physical id: | 2 | ||||||
logical name: | eth0.997 | ||||||
serial: | 00:17:9a:3a:77:93 | ||||||
capabilities: | ethernet physical | ||||||
configuration: |
|
id: | network:2 | ||||||
description: | Ethernet interface | ||||||
physical id: | 3 | ||||||
logical name: | eth0.991 | ||||||
serial: | 00:17:9a:3a:77:93 | ||||||
capabilities: | ethernet physical | ||||||
configuration: |
|
id: | network:3 | ||||||||||||||||||
description: | Ethernet interface | ||||||||||||||||||
physical id: | 4 | ||||||||||||||||||
logical name: | xenbr994 | ||||||||||||||||||
serial: | 00:06:5b:3a:3b:1e | ||||||||||||||||||
capabilities: | ethernet physical | ||||||||||||||||||
configuration: |
|
id: | network:4 | ||||||
description: | Ethernet interface | ||||||
physical id: | 5 | ||||||
logical name: | eth1.994 | ||||||
serial: | 00:06:5b:3a:3b:1e | ||||||
capabilities: | ethernet physical | ||||||
configuration: |
|
id: | network:5 | ||||||||||||||||||
description: | Ethernet interface | ||||||||||||||||||
physical id: | 6 | ||||||||||||||||||
logical name: | xenbr995 | ||||||||||||||||||
serial: | 00:06:5b:3a:3b:1e | ||||||||||||||||||
capabilities: | ethernet physical | ||||||||||||||||||
configuration: |
|
id: | network:6 | ||||||
description: | Ethernet interface | ||||||
physical id: | 7 | ||||||
logical name: | eth1.995 | ||||||
serial: | 00:06:5b:3a:3b:1e | ||||||
capabilities: | ethernet physical | ||||||
configuration: |
|
id: | network:7 | ||||||||||||||||||
description: | Ethernet interface | ||||||||||||||||||
physical id: | 8 | ||||||||||||||||||
logical name: | xenbr998 | ||||||||||||||||||
serial: | 00:06:5b:3a:3b:1e | ||||||||||||||||||
capabilities: | ethernet physical | ||||||||||||||||||
configuration: |
|
id: | network:8 | ||||||
description: | Ethernet interface | ||||||
physical id: | 9 | ||||||
logical name: | eth1.998 | ||||||
serial: | 00:06:5b:3a:3b:1e | ||||||
capabilities: | ethernet physical | ||||||
configuration: |
|
id: | network:9 | ||||||||||||||||||
description: | Ethernet interface | ||||||||||||||||||
physical id: | a | ||||||||||||||||||
logical name: | xenbr999 | ||||||||||||||||||
serial: | 00:06:5b:3a:3b:1e | ||||||||||||||||||
capabilities: | ethernet physical | ||||||||||||||||||
configuration: |
|
id: | network:10 | ||||||
description: | Ethernet interface | ||||||
physical id: | b | ||||||
logical name: | eth1.999 | ||||||
serial: | 00:06:5b:3a:3b:1e | ||||||
capabilities: | ethernet physical | ||||||
configuration: |
|
id: | network:11 | |||||||||||||||||||||
description: | Ethernet interface | |||||||||||||||||||||
physical id: | c | |||||||||||||||||||||
logical name: | xenbr992 | |||||||||||||||||||||
serial: | 00:17:9a:3a:77:93 | |||||||||||||||||||||
capabilities: | ethernet physical | |||||||||||||||||||||
configuration: |
|
id: | network:12 | ||||||
description: | Ethernet interface | ||||||
physical id: | d | ||||||
logical name: | eth0.992 | ||||||
serial: | 00:17:9a:3a:77:93 | ||||||
capabilities: | ethernet physical | ||||||
configuration: |
|